Preparation of Chemotherapy, Spills, and Cleaning a LAF Bench

Preparation

Preparation of chemotherapy outside of the pharmacy

For preparation of chemotherapy drugs, use gloves and a protective lab coat with long arms or tight-fitting cuffs.   Use two pairs of gloves where the inner pair is vinyl or other latex-free material. The outer glove should be sterile and of latex or other material which is impenetrable.  The gloves are recommended to be changed every half hour for preparation of chemotherapy drugs, and right away with spills.

  • Start the LAF-bench a minimum of 30 minutes before use.
  • Wash hands
  • Put on the inner gloves
  • Disinfect the work surface with 70% ethanol
  • Cover the work surface with a benchcoat. This should not cover the vent; otherwise, the bench will not function properly.
  • Read the dilution directions and find the necessary equipment and medications as described.
  • Choice of dilution system/fluids
    • A transfer cannula should be used in preference to a syringe where possible to maintain a closed system as much as possible.
    • If a syringe is used: use a syringe with Luer lock connection. These have a better connection between the syringe and the cannula.
  • Check the expiration on the drug packaging and infusion fluid.
  • Check that the drug in liquid form does not contain particles or visible solids.
  • Check that the packaging does not have any cracks or leakages.
  • Perform necessary calculations, date, and sign the work form.
  • Obtain another nurse to double check: right patient, work form, drug, dosage, fluid type and volume, as well as calculations.  All checks should be against the original ordination. The person doing the check should sign and date it.
  • Set out necessary equipment on the LAF-bench or where the work will take place. The equipment should be placed in the corner within the ventilation of the LAF-bench.  Remove the outer packaging of the sterile gloves and lay the gloves on the bench.
  • Put on the protective clothing (coat/apron and arm protectors)
  • Put on the sterile gloves in the bench
  • Disinfect the rubber membrane on the infusion bag and hood windows as well as the ampules.
  • Make sure the protective glass on the LAF-bench is pulled down to the correct work level as recommended by the manufacturer of the bench.

Handling of chemotherapy spills

All, except the workers who clean the spill, should leave the room.  Preferably, two people should help each other to remove the spill.  This way, one can ensure that proper precautions are taken.

At Oslo University Hospital, a packet is available from the pharmacy for chemotherapy spills.

Washing of LAF-bench

  • The LAF-bench should be operating under cleaning.
  • The sash should be down, as under normal working conditions.
  • Use a plastic apron, arm protectors, and gloves.

 

 