Preparation of Chemotherapy, Spills, and Cleaning a LAF Bench

Implementation

Preparation of chemotherapy drugs outside of a pharmacy

Aseptic procedure

  •   To avoid turbulence of the sterile, laminar air stream:
    • Work at least 15 cm inside the perforation with steady movements
    • Avoid hands or other objects from coming between the airflow and the medicine.
  • Make only one medicine at a time.
  • A full syringe or finished bag should be labeled for the next preparation.  The label should be labeled with the patients name, birthdate, drug and dosage, preparation date, expiration, and the name of the person who prepared and checked the medicine.
  • Avoid spills and aerosol formation
    • Use a dry, sterile compress around neck of the ampule when it is broken.
    • When the cannula is removed from the syringe, hold a sterile compress around the barrel neck to catch any spills.
    • Hold the syringe/ampule such that the opening is directed away from the face.
    • For solid substances, solvent should be added along the glass wall to avoid whirling of particles.
    • With positive/negative pressure in the hood glass: apply a filter cannula first to reduce pressure.
    • With use of adapter: place adapter first in the infusion bag and connect to the hood glass with medicine.
    • When the air is removed from the syringe, place the cannula cap on the cannula again while the syringe is held vertically with the cannula upright. A sterile compress should be held around the opening between the cannula and the syringe to collect spillage.
    • Clean up spills at once
  • After each addition, the contents of the infusion container should be mixed well by inverting and repeating 5-6 times.
  • Infusion fluid which has been added to should be marked satisfactorily.
  • The finished solution should be scrutinized for solid or foreign particles. All solid should be dissolved.
  • If visible changes occur under the mixing procedure, the physician should be contacted and the fluid should not be used. Store the infusion fluid and packaging of the added drug and contact the pharmacy (chemist) for further clarification.
  • All used equipment should be rolled up in the benchcoat (alternatively, all used equipment can be placed in a plastic bag which can be tied or closed with zipper) and disposed of in box with plastic bag for chemotherapy waste/biohazardous waste.
  • LAF-bench should be stopped at least 30 minutes after use.

Multiple additions

  • Addition of multiple drugs for chemotherapy solutions should be avoided. If it is still appropriate, there should be clear documentation of the mixture.
  • Different chemotherapies can mix if their mixing properties are documented (and checked with pharmacist).

Handling of chemotherapy spills

  • Use two pairs of disposable latex\nitrile gloves, plastic coat, mask, shoe covers (used with floor spills) and protective goggles.
  • Lay the smallest diaper in the middle of the spilled fluid. Then, place the absorbent bed sheet over the diaper and the rest of the fluid. Use more diapers and absorbent material if necessary.
  • Dispose of used diapers, absorbent material, bed sheets, and gloves is appropriate waste container, which can be closed.
  • Use new gloves and wash thereafter with soapy water and disposable wash cloths a minimum of three times. Use a new cloth before each wash. Used cloths should not be put back in the wash solution.  Used cloths and gloves should be disposed in the appropriate waste containers (in plastic bags which can be closed).
  • The plastic bags with used equipment should be disposed of in the appropriate containers which are properly labeled.

Washing of LAF-bench

  • Other than a cannula bucket, nothing should be stored in the bench after the last preparation.
  • Washing with 70% ethanol is sufficient if there are no visible spills.
  • For visible spills, wash the bench with soapy water and spray afterwards with 70% ethanol (see procedure under). Soapy water is the most effective for removing chemotherapy spills.

Routine washing

  • Washing should be done every 1-4 weeks depending on frequency of use.
  • Spills and dust pose risks for washing.
  • It is important that any remaining solution of chemotherapy is not spread under washing.
  • Use disposable cloths.
  • To avoid contamination of washing water, the washing hand should not be dipped in the water.
  • Wash with slow movements and use a new cloth as needed.
  • Cloths that have been in contact with the bench should not be put back in the washing water and should be discarded in proper waste container.
  • Wash first the walls from top to bottom with soapy water (the cleanest to the most contaminated) – place the cloth on a squeegee for hard-to-reach areas.
  • The filter in the ceiling of the bench should not be washed.
  • Wash the work surface in the bench – wash from back to forward (from the cleanest to the most contaminated).
  • Raise the work surface.
  • Wash the work surface on the underside, especially the closest, perforated part.
  • Then wash the underside bottom of the work surface.
  • Wash thereafter all surfaces (not the ceiling) with 70% ethanol.
  • Remove protective clothing.
  • Discard all protective clothing for one-time use and washcloths in the appropriate waste container.
  • Wash hands.
  • Replace the cannula bucket.
  • There should be a record for bench washing; the employee who washes should sign and date the record.